Loss of the Bus of the Cabin Pressure Controller 2 by the SDAC1
TASK 31-54-00-810-934-A
Loss of the Bus of the Cabin Pressure Controller 2 by the SDAC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-131-A
Subtask 31-54-00-810-183-B
[Rev.8 from Aug 2018]
2026.04.04 04:30:33 UTC
Loss of the Bus of the Cabin Pressure Controller 2 by the SDAC1
1. Possible Causes
- SDAC-1 [1WV1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-131-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-301-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
Subtask 31-54-00-810-183-B
A. If the test gives the maintenance message:
SDAC1: NO DATA FROM CPC2
Subtask 31-54-00-710-302-A SDAC1: NO DATA FROM CPC2
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from SDAC 1 (1WV1) pins AE/13C, 13D to the first terminal block ASM 315403.
B. Do the test given in Para. 3.B.