Failure of the SDAC 2 Pin Programming
TASK 31-54-00-810-929-A
Failure of the SDAC 2 Pin Programming
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-291-A 4. Fault Isolation
Subtask 31-54-00-810-178-A
[Rev.8 from Aug 2018]
2026.04.04 04:40:06 UTC
Failure of the SDAC 2 Pin Programming
1. Possible Causes
- SDAC-2 [1WV2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-50-00-740-002 | Read and Decode the Hardware Pin Programming of the SDAC and FWC |
| AWM 315406 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-291-A 4. Fault Isolation
Subtask 31-54-00-810-178-A
A. If the test gives the maintenance message SDAC2 PIN PROGRAM FAIL:
(a) If the pin programming is incorrect:
Subtask 31-54-00-710-292-A - read the SDAC 2 pin programming AMM 31-50-00-740-002.
(a) If the pin programming is incorrect:
- repair the aircraft wiring.
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Do the test given in Para. 3.