Unwanted Tripping of a Circuit Breaker on the AC/DC Emergency Power Center
TASK 31-54-00-810-926-A
Unwanted Tripping of a Circuit Breaker on the AC/DC Emergency Power Center
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-860-058-A Subtask 31-54-00-710-286-A
Subtask 31-54-00-810-175-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:32 UTC
Unwanted Tripping of a Circuit Breaker on the AC/DC Emergency Power Center
1. Possible Causes
- defective circuit breaker
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 315406 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
Subtask 31-54-00-860-058-A Subtask 31-54-00-710-286-A
B. Test
Make sure that a warning is shown on the upper ECAM DU.
4. Fault IsolationMake sure that a warning is shown on the upper ECAM DU.
Subtask 31-54-00-810-175-A
A. If the upper ECAM DU gives the warning message C/B TRIPPED L ELEC BAY:
1 If there is an isolation fault:
Subtask 31-54-00-860-059-A - do a check of the status of the circuit breakers on the AC/DC emergency power center (106VU).
- do a check for correct continuity between pin 3 (GND signal) and pin 4 for each of these circuit breakers on AC/DC emergency power center (106VU) ASM 315406.
- replace the defective circuit breaker .
NOTE: On ground you must not close a tripped circuit breaker without trouble shooting of the related system.
(a) Do an isolation check of the wiring between the C/B and the related system. 1 If there is an isolation fault:
- repair the wiring between the C/B and the related system.
- Close the tripped circuit breaker(s).
B. Do the EIS start procedure given in Para. 3.A.
(1) Make sure that the warning message is no longer shown.
(2) Do the EIS stop procedure AMM 31-60-00-860-002.
(1) Make sure that the warning message is no longer shown.
(2) Do the EIS stop procedure AMM 31-60-00-860-002.