Failure of the SDAC1 and SDAC2
TASK 31-54-00-810-918-A
Failure of the SDAC1 and SDAC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-272-A 4. Fault Isolation
Subtask 31-54-00-810-167-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:00 UTC
Failure of the SDAC1 and SDAC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-272-A 4. Fault Isolation
Subtask 31-54-00-810-167-A
A. If the test gives the maintenance messages
NO DATA FROM SDAC1 and NO DATA FROM SDAC2.
Subtask 31-54-00-710-273-A NO DATA FROM SDAC1 and NO DATA FROM SDAC2.
- replace the SDAC-1 [1WV1] and the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Do the test given in Para. 3.