W DOC AIRBUS | TSM A320F

Loss of the Output Bus 2 of the Zone Temperature Controller by the SDAC 1


TASK 31-54-00-810-915-A
Loss of the Output Bus 2 of the Zone Temperature Controller by the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-266-A
A. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-164-A
A. If the test gives the maintenance message SDAC 1 : NO DATA FROM ECS 2:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/14A, 14B to the first terminal block ASM 315403.
Subtask 31-54-00-710-267-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:31 UTC