W DOC AIRBUS | TSM A320F

Loss of the PACK 2 CONT Bus or the ACSC2 Bus to the SDAC 1


TASK 31-54-00-810-907-A
Loss of the PACK 2 CONT Bus or the ACSC2 Bus to the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • P2 CONTROLLER [27HH]
  • wiring
  • CONT-AIR COND SYSTEM 2 [57HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-125-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
Subtask 31-54-00-710-250-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-156-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : NO DATA FROM PACK2 CONT:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/13A, 13B to the first terminal block , ASM 315403.
Subtask 31-54-00-810-156-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

SDAC1 : NO DATA FROM ACSC2

   (1) If the fault continues:

   (2) If the fault continues:

  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/13A, 13B to the Air Conditioning System Controller 2 pins AA/7E, 7F, ASM 315403.
Subtask 31-54-00-710-251-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:30:30 UTC