Loss of the PACK 1 CONT Bus or the ACSC1 Bus to the SDAC 1
TASK 31-54-00-810-905-A
Loss of the PACK 1 CONT Bus or the ACSC1 Bus to the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-123-A
Subtask 31-54-00-810-154-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:30 UTC
Loss of the PACK 1 CONT Bus or the ACSC1 Bus to the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-123-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-246-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
Subtask 31-54-00-810-154-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : NO DATA FROM PACK1 CONT:
Subtask 31-54-00-810-154-B ** ON A/C NOT FOR ALL - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- replace P1 CONTROLLER [7HH] , AMM 21-61-34-000-001 and AMM 21-61-34-400-001
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13J, 13K to the first terminal block , ASM 315403.
A. If the test gives the maintenance message:
SDAC1 : NO DATA FROM ACSC1
Subtask 31-54-00-710-247-A SDAC1 : NO DATA FROM ACSC1
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- replace CONT-AIR COND SYSTEM 1 [47HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13J, 13K to the Air Conditioning System Controller 1 pins AA/7E, 7F, ASM 315403.
B. Do the test given in Para. 3.B.