Loss of the GPCU/EGIU 1 Bus of the SDAC 1
TASK 31-54-00-810-903-A
Loss of the GPCU/EGIU 1 Bus of the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-242-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-152-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:30 UTC
Loss of the GPCU/EGIU 1 Bus of the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-22-33-000-001 | Removal of the EGIU-1(2) |
| AMM 24-22-33-400-002 | Installation of the EGIU-1(2) |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-242-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-152-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : NO DATA FROM EGIU1-2:
Subtask 31-54-00-710-243-A ** ON A/C NOT FOR ALL - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- replace the EGIU-1 [22XU1] , AMM 24-22-33-000-001 and AMM 24-22-33-400-002.
- do a check and repair the
wiring from the SDAC 1 (1WV1) to the EGIU 1 (22XU1) from pins AE/10A, 10B to pins AB/13A, 13B ASM 315403.
B. Do the test given in Para. 3.