Loss of the GCU 1/EGIU 1 Bus of the SDAC 1
TASK 31-54-00-810-901-A
Loss of the GCU 1/EGIU 1 Bus of the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-238-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-150-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:30 UTC
Loss of the GCU 1/EGIU 1 Bus of the SDAC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-22-33-000-001 | Removal of the EGIU-1(2) |
| AMM 24-22-33-400-002 | Installation of the EGIU-1(2) |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-238-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-150-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : NO DATA FROM EGIU1-1:
Subtask 31-54-00-710-239-A ** ON A/C NOT FOR ALL - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- replace the EGIU-1 [22XU1] , AMM 24-22-33-000-001 and AMM 24-22-33-400-002.
- do a check and repair the
wiring from the SDAC 1 (1WV1) to the EGIU 1 (22XU1) from pins AB/10G, 10H to pins AA/1A, 1B ASM 315403.
B. Do the test given in Para. 3.