W DOC AIRBUS | TSM A320F

Loss of the GCU 2/EGIU 2 Bus of the SDAC 1


TASK 31-54-00-810-899-A
Loss of the GCU 2/EGIU 2 Bus of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • EGIU-2 [22XU2]
  • wiring from the SDAC 1 (1WV1) to the EGIU 2 (22XU2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-33-000-001
Removal of the EGIU-1(2)
AMM 24-22-33-400-002
Installation of the EGIU-1(2)
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-234-A ** ON A/C NOT FOR ALL
A. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-148-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : NO DATA FROM EGIU2-1:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) to the EGIU 2 (22XU2) from pins AE/10C, 10D to pins AA/1A, 1B ASM 315403.
Subtask 31-54-00-710-235-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:29 UTC