Loss of the BSCU Bus 2 of the SDAC 2
TASK 31-54-00-810-896-A
Loss of the BSCU Bus 2 of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-228-A 4. Fault Isolation
Subtask 31-54-00-810-145-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:29 UTC
Loss of the BSCU Bus 2 of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-228-A 4. Fault Isolation
Subtask 31-54-00-810-145-A
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BSCU1:
Subtask 31-54-00-710-229-A - replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/14G, 14H to the first terminal block , ASM 315403.
B. Do the test given in Para. 3.