Failure of the Three Axis Accelerometer
TASK 31-54-00-810-894-A
Failure of the Three Axis Accelerometer
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-122-A
Subtask 31-54-00-810-143-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:29 UTC
Failure of the Three Axis Accelerometer
1. Possible Causes
- ACCELEROMETER-THREE AXIS [6TU]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-33-16-000-001 | Removal of the Three-Axis-Accelerometer (LA) |
| AMM 31-33-16-400-001 | Installation of the Three-Axis-Accelerometer (LA) |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315402 |
Subtask 31-54-00-865-122-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-224-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
Subtask 31-54-00-810-143-A
A. If the test gives the maintenance message SDAC1 : ACCELEROMETER 6TU:
Subtask 31-54-00-710-225-A - replace the ACCELEROMETER-THREE AXIS [6TU] , AMM 31-33-16-000-001 and AMM 31-33-16-400-001.
- do a check of the wiring from accelerometer (6TU) pins A/C, D to the first terminal block
- repair the wiring
- do a check of the wiring from accelerometer (6TU) pins A/E, F to the first terminal block
- repair the wiring
- do a check and repair the wiring from accelerometer (6TU) pins A/G, H to the first terminal block ASM 315402.
B. Do the test given in Para. 3.