Loss of the TR 1 CURRENT Bus of the SDAC 2
TASK 31-54-00-810-876-A
Loss of the TR 1 CURRENT Bus of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-104-A
Subtask 31-54-00-810-125-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:28 UTC
Loss of the TR 1 CURRENT Bus of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 243202 | |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-104-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-188-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 123VU | TR1/SPLY | 2PU1 | AB10 |
Subtask 31-54-00-810-125-A
A. If the test gives the maintenance message:
SDAC 2 : NO TR 1 CURRENT 1PU1:
Subtask 31-54-00-710-189-A SDAC 2 : NO TR 1 CURRENT 1PU1:
- replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/14C, 14D to the first terminal block , ASM 243202.
B. Do the test given in Para. 3.B.