Loss of the TR 2 VOLTAGE Input of the SDAC 2


TASK 31-54-00-810-874-A
Loss of the TR 2 VOLTAGE Input of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 243201
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-102-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
123VUTR2/214XP/SPLY2PU2AB04
Subtask 31-54-00-710-184-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-123-A
A. If the test gives the maintenance message SDAC 2 : NO TR 2 VOLTAGE 1PU2:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) pin AE/6A to the first terminal block , ASM 243201.
Subtask 31-54-00-710-185-A
B. Do the test given in Para. 3.B.