Loss of the TR 2 CURRENT Bus of the SDAC 2
TASK 31-54-00-810-872-A
Loss of the TR 2 CURRENT Bus of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-100-A
Subtask 31-54-00-810-121-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:28 UTC
Loss of the TR 2 CURRENT Bus of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 243201 | |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-100-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-180-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 123VU | TR2/214XP/SPLY | 2PU2 | AB04 |
Subtask 31-54-00-810-121-A
A. If the test gives the maintenance message SDAC 2 : NO TR 2 CURRENT 1PU2:
Subtask 31-54-00-710-181-A - replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AE/14G, 14H to the first terminal block , ASM 243201.
B. Do the test given in Para. 3.B.