W DOC AIRBUS | TSM A320F

Loss of the EMER GEN VOLTAGE and FREQ Input of the SDAC 2


TASK 31-54-00-810-870-A
Loss of the EMER GEN VOLTAGE and FREQ Input of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242401
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-176-A
A. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-119-A
A. If the test gives the maintenance message SDAC 2 : GLC EMER CNTOR 2XE:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) pin AE/8B to the first terminal block , ASM 242401.
Subtask 31-54-00-710-177-A
B. Do the test given in Para. 3.