W DOC AIRBUS | TSM A320F

Loss of the SFCC 2 Bus of the SDAC 2


TASK 31-54-00-810-868-A
Loss of the SFCC 2 Bus of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-172-A
A. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-117-A
A. If the test gives the maintenance message SDAC 2 : NO DATA FROM SFCC 2:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/11A, 11B to the first terminal block , ASM 315403.
Subtask 31-54-00-710-173-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:28 UTC