Loss of the SFCC 2 Bus of the SDAC 1
TASK 31-54-00-810-867-A
Loss of the SFCC 2 Bus of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-170-A 4. Fault Isolation
Subtask 31-54-00-810-116-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:28 UTC
Loss of the SFCC 2 Bus of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-170-A 4. Fault Isolation
Subtask 31-54-00-810-116-A
A. If the test gives the maintenance message SDAC 1 : NO DATA FROM SFCC 2:
Subtask 31-54-00-710-171-A - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/11A, 11B to the first terminal block , ASM 315403.
B. Do the test given in Para. 3.