Loss of the BLUE RSVR AIR PRESSURE Input of the SDAC 2
TASK 31-54-00-810-864-A
Loss of the BLUE RSVR AIR PRESSURE Input of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-164-A 4. Fault Isolation
Subtask 31-54-00-810-113-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:28 UTC
Loss of the BLUE RSVR AIR PRESSURE Input of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315402 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-164-A 4. Fault Isolation
Subtask 31-54-00-810-113-A
A. If the test gives the maintenance message SDAC 2 : B HYD AIR PRESS XMTR 2385GH:
Subtask 31-54-00-710-165-A - replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/11E, 11F to the first terminal block , ASM 315402.
B. Do the test given in Para. 3.