W DOC AIRBUS | TSM A320F

Loss of the BLUE RSVR TEMP Input of the SDAC 2


TASK 31-54-00-810-860-A
Loss of the BLUE RSVR TEMP Input of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • TEMP TRANSM SWITCH [2381GR]
  • wiring from the SDAC 2 (1WV2) to the Blue reservoir temperature transmitter (2381GR)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 293301
AMM 29-33-11-000-002
Removal of the Temperature Transmitter
AMM 29-33-11-400-002
Installation of the Temperature Transmitter
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-156-A
A. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-109-A
A. If the test gives the maintenance message SDAC2 : B HYD TEMP XMTR 2381GR:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) to the Blue reservoir temperature transmitter (2381GR) from pins AB/11A, 11B to pins A/J, K , ASM 293301.
Subtask 31-54-00-710-157-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:27 UTC