Loss of the BMC 2 Bus of the SDAC 2
TASK 31-54-00-810-854-A
Loss of the BMC 2 Bus of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-093-A
Subtask 31-54-00-810-103-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:27 UTC
Loss of the BMC 2 Bus of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315403 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-093-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-144-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
Subtask 31-54-00-810-103-A
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BMC2:
Subtask 31-54-00-710-145-A - replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AE/12C, 12D to the first terminal block , ASM 315403.
B. Do the test given in Para. 3.