Loss of the BMC 2 Bus of the SDAC 1


TASK 31-54-00-810-853-A
Loss of the BMC 2 Bus of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-092-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 31-54-00-710-142-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-102-A
A. If the test gives the maintenance message SDAC1 : NO DATA FROM BMC2:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/12C, 12D to the first terminal block , ASM 315403.
Subtask 31-54-00-710-143-A
B. Do the test given in Para. 3.