Loss of the BCL 1 Bus of the SDAC 2


TASK 31-54-00-810-852-A
Loss of the BCL 1 Bus of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • BCL-1 [1PB1]
  • wiring from the SDAC 2 (1WV2) to the BCL 1 (1PB1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-091-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/BAT REF/BCL19PB1F01
105VUELEC/BAT BUS/REF/BCL18PB1G01
Subtask 31-54-00-710-140-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-101-A
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BCL1
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) to the BCL 1 (1PB1) from pins AB/11G, 11H to pins A/<D, <E ASM 315403.
Subtask 31-54-00-710-141-A
B. Do the test given in Para. 3.