Loss of the BCL 2 Bus of the SDAC 1


TASK 31-54-00-810-849-A
Loss of the BCL 2 Bus of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • BCL-2 [1PB2]
  • wiring from the SDAC 1 (1WV1) to the BCL 2 (1PB2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-088-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/BAT REF/BCL29PB2F02
105VUELEC/BAT BUS/REF/BCL28PB2J02
Subtask 31-54-00-710-134-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-098-A
A. If the test gives the maintenance message SDAC1 : NO DATA FROM BCL2
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) to the BCL 2 (1PB2) from pins AE/11C, 11D to pins A/P, R ASM 315403.
Subtask 31-54-00-710-135-A
B. Do the test given in Para. 3.