Loss of the OXYGEN HP Input of the SDAC 1
TASK 31-54-00-810-845-A
Loss of the OXYGEN HP Input of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-084-A
Subtask 31-54-00-810-094-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:26 UTC
Loss of the OXYGEN HP Input of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315402 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-084-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-126-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
Subtask 31-54-00-810-094-A
A. If the test gives the maintenance message SDAC1 : OX PRESS REG XMTR 4HT
Subtask 31-54-00-710-127-A - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13E, 13F to the first terminal block , ASM 315402.
B. Do the test given in Para. 3.