W DOC AIRBUS | TSM A320F

Loss of the OXYGEN HP Input of the SDAC 1


TASK 31-54-00-810-845-A
Loss of the OXYGEN HP Input of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315402
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-084-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUOXYGEN/CREW/OXY/SPLY1HTHA01
Subtask 31-54-00-710-126-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-094-A
A. If the test gives the maintenance message SDAC1 : OX PRESS REG XMTR 4HT
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13E, 13F to the first terminal block , ASM 315402.
Subtask 31-54-00-710-127-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:26 UTC