Loss of the YELLOW RSVR QTY Input of the SDAC 1
TASK 31-54-00-810-835-A
Loss of the YELLOW RSVR QTY Input of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-074-A
Subtask 31-54-00-810-084-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:26 UTC
Loss of the YELLOW RSVR QTY Input of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
wiring from the SDAC 1 (1WV1) pins AE/6H, 6J, 6K to the first terminal block wiring from the SDAC 1 (1WV1) pin AC/4 to the C/B 9WV - C/B-EIS/SDAC/1/BUS1/26VAC SYNC AC [9WV]
wiring from the SDAC 1 (1WV1) pin AC/4 to the C/B 1831GQ - C/B-HYDRAULIC/HYD/QTY/IND [1831GQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315101 | |
| ASM 315402 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-074-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-106-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
Subtask 31-54-00-810-084-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : Y HYD QTY IND 3000GQ:
Subtask 31-54-00-810-084-B ** ON A/C NOT FOR ALL - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the
wiring from the SDAC 1 (1WV1) pins AE/6H, 6J, 6K to the first terminal block , ASM 315402.
- do a check for continuity of the
wiring from the SDAC 1 (1WV1) pin AC/4 to the C/B 9WV , ASM 315101.
- replace the C/B-EIS/SDAC/1/BUS1/26VAC SYNC AC [9WV] .
A. If the test gives the maintenance message SDAC1 : Y HYD QTY IND 3000GQ:
Subtask 31-54-00-710-107-A - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the
wiring from the SDAC 1 (1WV1) pins AE/6H, 6J, 6K to the first terminal block , ASM 315402.
- do a check for continuity of the
wiring from the SDAC 1 (1WV1) pin AC/4 to the C/B 1831GQ , ASM 315101.
- replace the C/B-HYDRAULIC/HYD/QTY/IND [1831GQ] .
B. Do the test given in Para. 3.B.