Loss of the GREEN RSVR QTY Input of the SDAC 2
TASK 31-54-00-810-834-A
Loss of the GREEN RSVR QTY Input of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-073-A
Subtask 31-54-00-810-083-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:25 UTC
Loss of the GREEN RSVR QTY Input of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
wiring from the SDAC 2 (1WV2) pins AB/6A, 6B, 6C to the first terminal block wiring from the SDAC 2 (1WV2) pin AC/4 to the C/B 10WV - C/B-EIS/SDAC/2/BUS1/26VAC SYNC AC [10WV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315101 | |
| ASM 315402 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-073-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-104-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
Subtask 31-54-00-810-083-A
A. If the test gives the maintenance message SDAC2 : G HYD QTY IND 1000GQ:
Subtask 31-54-00-710-105-A - replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the
wiring from the SDAC 2 (1WV2) pins AB/6A, 6B, 6C to the first terminal block , ASM 315402.
- do a check for continuity of the
wiring from the SDAC 2 (1WV2) pin AC/4 to the C/B 10WV , ASM 315101.
- replace the C/B-EIS/SDAC/2/BUS1/26VAC SYNC AC [10WV] .
B. Do the test given in Para. 3.B.