Loss of the ENG 2 OIL PRESS Input of the SDAC 1
TASK 31-54-00-810-829-A
Loss of the ENG 2 OIL PRESS Input of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-068-A
Subtask 31-54-00-810-078-B
[Rev.8 from Aug 2018]
2026.04.04 04:30:25 UTC
Loss of the ENG 2 OIL PRESS Input of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| ASM 793601 |
Subtask 31-54-00-865-068-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-094-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/OIL/PRESS | 2EN2 | N42 |
Subtask 31-54-00-810-078-B
A. If the test gives the maintenance message SDAC1 : ENG2 OIL PRESS XMTR 4003EN:
Subtask 31-54-00-710-095-A - replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/15G, 15H to the first terminal block , ASM 793601.
B. Do the test given in Para. 3.