Loss of the L Yellow Brake Pressure-Transducer Input of the SDAC 1 and SDAC 2
TASK 31-54-00-810-819-A
Loss of the L Yellow Brake Pressure-Transducer Input of the SDAC 1 and SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-058-A
Subtask 31-54-00-810-068-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:24 UTC
Loss of the L Yellow Brake Pressure-Transducer Input of the SDAC 1 and SDAC 2
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AWM 315470 |
Subtask 31-54-00-865-058-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-074-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | L/G/Y BRK/PRESS/IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | ABCU &/Y BRK/PRESS IND | 61GG | C10 |
Subtask 31-54-00-810-068-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : LH Y BRK PRESS XDCR 63GG:
Subtask 31-54-00-810-068-B ** ON A/C NOT FOR ALL - do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13C, 13D to the first terminal block , AWM 315470.
A. If the test gives the maintenance message SDAC1 : LH Y BRK PRESS XDCR 101GG:
Subtask 31-54-00-710-075-A - do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/13C, 13D to the first terminal block , AWM 315470.
B. Do the test given in Para. 3.B.