W DOC AIRBUS | TSM A320F

Loss of the ARINC 429 Bus 2 Output of the SDAC 1


TASK 31-54-00-810-809-A
Loss of the ARINC 429 Bus 2 Output of the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315404
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-066-A
A. Test
Do the ground scanning of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-064-A
A. If the test gives the maintenance message:
FWC2 : NO DATA FROM SDAC1
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 1 (1WV1) pins AE/9B, 9C to the first terminal block , ASM 315404.
Subtask 31-54-00-710-067-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:24 UTC