Loss of the ARINC 429 Bus 1 Output of the SDAC 2
TASK 31-54-00-810-801-A
Loss of the ARINC 429 Bus 1 Output of the SDAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-050-A 4. Fault Isolation
Subtask 31-54-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:23 UTC
Loss of the ARINC 429 Bus 1 Output of the SDAC 2
1. Possible Causes
- SDAC-2 [1WV2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315404 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-050-A 4. Fault Isolation
Subtask 31-54-00-810-050-A
A. If the test gives the maintenance message:
FWC1 : NO DATA FROM SDAC2
Subtask 31-54-00-710-051-A FWC1 : NO DATA FROM SDAC2
- replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 2 (1WV2) pins AB/9G, 9H to the first terminal block , ASM 315404.
B. Do the test given in Para. 3.