Loss of the RH FLP SYNC Signal Output by the FWC 2
TASK 31-53-00-810-983-A
Loss of the RH FLP SYNC Signal Output by the FWC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-342-A 4. Fault Isolation
Subtask 31-53-00-810-238-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:23 UTC
Loss of the RH FLP SYNC Signal Output by the FWC 2
1. Possible Causes
- FWC-2 [1WW2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 275501 | |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-342-A 4. Fault Isolation
Subtask 31-53-00-810-238-A
A. If the test gives the maintenance message FWC2: RH FLP SYNC 3CNB:
Subtask 31-53-00-710-343-A - Replace the FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- Do a check and repair the defective wiring , from the FWC2 (1WW2) pins AD/13F, 13G, 13H to the first terminal block ASM 275501.
B. Do the test given in Para. 3.