W DOC AIRBUS | TSM A320F

Loss of the CSAS Bus of the FWC 2


TASK 31-53-00-810-973-A
Loss of the CSAS Bus of the FWC 2


1. Possible Causes
  • FWC-2 [1WW2]
  • wiring of the CSAS CONTROL UNIT signal
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315203
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-710-324-A
A. Test
Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-226-A
A. If the test gives the maintenance message FWC2 : NO DATA FROM CSAS:
   (1) If the fault continues:
  • do a check and repair the wiring of the CSAS CONTROL UNIT signal from FWC 2 (1WW2) pins AB/6G, 6H to CSAS control unit (100HW) pins AB/12E, 12F ASM 315203.
Subtask 31-53-00-710-325-A
B. Do the test given in Para. 3.