Loss of the Data Output Bus of the FWC2
TASK 31-53-00-810-967-A
Loss of the Data Output Bus of the FWC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-311-A 4. Fault Isolation
Subtask 31-53-00-810-201-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:22 UTC
Loss of the Data Output Bus of the FWC2
1. Possible Causes
- FWC-2 [1WW2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315205 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-311-A 4. Fault Isolation
Subtask 31-53-00-810-201-A
A. If the test gives the maintenance message:
FWC1 :NO DATA FROM OPPOSITE FWC
(b) from the FWC 2 (1WW2) pins AB/12F, 12G to the first terminal block.
(c) from the FWC 2 (1WW2) pins AB/12J, 12K to the first terminal block.
Subtask 31-53-00-710-312-A FWC1 :NO DATA FROM OPPOSITE FWC
- replace the FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the wiring ASM 315205:
(b) from the FWC 2 (1WW2) pins AB/12F, 12G to the first terminal block.
(c) from the FWC 2 (1WW2) pins AB/12J, 12K to the first terminal block.
B. Do the test given in Para. 3.