Detection of incorrect AOA value from the ADR1 to the FWC2


TASK 31-53-00-810-953-A
Detection of incorrect AOA value from the ADR1 to the FWC2


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-19-000-001
Removal of the Angle of Attack Sensor
AMM 34-11-19-200-001
Inspection of the Angle-Of-Attack Sensor
AMM 34-11-19-400-001
Installation of the Angle of Attack Sensor
AMM 34-13-00-710-006
Operational Test of the AOA SENSOR TEST
3. Fault Confirmation
Subtask 31-53-00-710-291-A
A. Not applicable
4. Fault Isolation
Subtask 31-53-00-810-191-B
A. If the PFR gives the maintenance message FWC2 :ADC1 (1FP1) AOA SIGNAL and the maintenance status NAV CAPT AOA FAULT:
   (1) Do a check of the AOA sensor 1 AMM 34-11-19-200-001.
     (a) If there is a hard point or damage on the vane, replace the AOA sensor 1 AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
   (2) Do the operational test of the AOA SENSOR TEST AMM 34-13-00-710-006.
     (a) If the results of the test are not satisfactory: