Loss of the RH SLT SYNC Signal Output by the FWC2
TASK 31-53-00-810-943-A
Loss of the RH SLT SYNC Signal Output by the FWC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-281-A 4. Fault Isolation
Subtask 31-53-00-810-186-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:21 UTC
Loss of the RH SLT SYNC Signal Output by the FWC2
1. Possible Causes
- FWC-2 [1WW2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 278501 | |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-281-A 4. Fault Isolation
Subtask 31-53-00-810-186-A
A. If the test gives the maintenance message FWC2: RH SLT SYNC 4CNB:
Subtask 31-53-00-710-282-A - replace the FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the defective wiring , from the FWC2 (1WW2) pins AD/13A, 13B, 13C to the first terminal block ASM 278501.
B. Do the test given in Para. 3.