W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the FWC2 detected by the CFDIU


TASK 31-53-00-810-914-A
Loss of the Bus Output from the FWC2 detected by the CFDIU


1. Possible Causes
  • FWC-2 [1WW2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 315205
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-865-065-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/FWC2/SPLY2WWQ07
Subtask 31-53-00-740-076-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-53-00-810-163-A
A. If the test gives the maintenance message NO FWC2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from FWC 2 (1WW2) pins AB/12J, 12K to the first terminal block ASM 315205.
Subtask 31-53-00-740-077-A
B. Do the test given in Para. 3.B.