W DOC AIRBUS | TSM A320F

Loss of the TCAS Output Bus Detected by the FWC1


TASK 31-53-00-810-906-A
Loss of the TCAS Output Bus Detected by the FWC1


1. Possible Causes
  • CMPTR-TCAS [1SG]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 344301
AMM 34-43-34-000-001
Removal of the TCAS Computer
AMM 34-43-34-400-001
Installation of the TCAS Computer
3. Fault Confirmation
Subtask 31-53-00-865-072-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/TCAS4SGK10
Subtask 31-53-00-710-246-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-155-A
A. If the test gives the maintenance message:
FWC1 : NO DATA FROM TCAS
   (1) If the fault continues:
  • do a check and repair the wiring from TCAS computer (1SG) pins AE/7C, 7D to the first terminal block ASM 344301.
Subtask 31-53-00-710-247-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:19 UTC