Loss of the input bus from the SDAC 2 to the FWC 1
TASK 31-53-00-810-900-A
Loss of the input bus from the SDAC 2 to the FWC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-234-A 4. Fault Isolation
Subtask 31-53-00-810-149-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:19 UTC
Loss of the input bus from the SDAC 2 to the FWC 1
1. Possible Causes
- FWC-1 [1WW1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315404 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-53-00-710-234-A 4. Fault Isolation
Subtask 31-53-00-810-149-A
A. If the test gives the maintenance message:
FWC1 : NO DATA FROM SDAC2
Subtask 31-53-00-710-235-A FWC1 : NO DATA FROM SDAC2
- replace the FWC-1 [1WW1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from FWC 1 (1WW1) pins AE/4A, 4B to the first terminal block , ASM 315404.
B. Do the test given in Para. 3.