W DOC AIRBUS | TSM A320F

Loss of the CIDS-SDF1 or SDCU Channel 1 Bus Detected by the FWC 2


TASK 31-53-00-810-892-A
Loss of the CIDS-SDF1 or SDCU Channel 1 Bus Detected by the FWC 2


1. Possible Causes
  • FWC-2 [1WW2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315203
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-710-218-A
A. Do the ground scanning of the central warning system (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-141-A
A. If the test gives the maintenance message:

FWC2 : NO DATA FROM SDCU1

or

FWC2 : NO DATA FROM CIDS-SDF1

   (1) If the fault continues:

  • do a check and repair the wiring from FWC 2 (1WW2) pins AB/8E, 8F to the first terminal block ASM 315203.
Subtask 31-53-00-710-219-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:18 UTC