Loss of the CFDIU Output Bus by the FWC 2
TASK 31-53-00-810-889-A
Loss of the CFDIU Output Bus by the FWC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-212-A 4. Fault Isolation
Subtask 31-53-00-810-138-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:18 UTC
Loss of the CFDIU Output Bus by the FWC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315203 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-212-A 4. Fault Isolation
Subtask 31-53-00-810-138-A
A. If the test gives the maintenance message FWC2 : NO DATA FROM CFDIU:
Subtask 31-53-00-710-213-A - replace the FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the FWC 2 (1WW2) from pins AB/2H, 2J to pins AE/5J, 5K ASM 315203.
B. Do the test given in Para. 3.