Loss of the LH FLP SYNC Signal Output of the Flap IPPU to the FWC 1
TASK 31-53-00-810-886-A
Loss of the LH FLP SYNC Signal Output of the Flap IPPU to the FWC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-206-A 4. Fault Isolation
Subtask 31-53-00-810-135-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:18 UTC
Loss of the LH FLP SYNC Signal Output of the Flap IPPU to the FWC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 275501 | |
| AMM 27-55-11-000-001 | Removal of the Instrumentation Position Pick-Off Unit |
| AMM 27-55-11-400-001 | Installation of the Instrumentation Position Pick-Off Unit |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-206-A 4. Fault Isolation
Subtask 31-53-00-810-135-A
A. If the test gives the maintenance message FWC1: LH FLP SYNC 3CNA:
Subtask 31-53-00-710-207-A - replace the FWC-1 [1WW1] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- replace the IPPU-FLAP [3CN] AMM 27-55-11-000-001 and AMM 27-55-11-400-001.
- do a check and repair the
wiring from the FWC 1 (1WW1) to the flap IPPU (3CN) , between pins AA/13B, 13C, 13D and pins A/C, D, E ASM 275501.
B. Do the test given in Para. 3.