Loss of the RH SLT SYNC Signal Output of the Slat IPPU to the FWC2
TASK 31-53-00-810-879-A
Loss of the RH SLT SYNC Signal Output of the Slat IPPU to the FWC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-192-A 4. Fault Isolation
Subtask 31-53-00-810-128-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:16 UTC
Loss of the RH SLT SYNC Signal Output of the Slat IPPU to the FWC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 278501 | |
| AMM 27-85-11-000-001 | Removal of the Instrumentation Position Pick-Off Unit |
| AMM 27-85-11-400-001 | Installation of the Instrumentation Position Pick-Off Unit |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-192-A 4. Fault Isolation
Subtask 31-53-00-810-128-A
A. If the test gives the maintenance message FWC2: RH SLT SYNC 4CNB:
Subtask 31-53-00-710-193-A - replace the FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- replace the IPPU-SLAT [4CN] AMM 27-85-11-000-001 and AMM 27-85-11-400-001.
- do a check and repair the
wiring from the FWC2 (1WW2) to the slat IPPU (4CN) , between pins AD/13A, 13B, 13C and pins B/C, D, E ASM 278501.
B. Do the test given in Para. 3.