W DOC AIRBUS | TSM A320F

Loss of the RH SLT SYNC Signal Output of the Slat IPPU to the FWC2


TASK 31-53-00-810-879-A
Loss of the RH SLT SYNC Signal Output of the Slat IPPU to the FWC2


1. Possible Causes
  • FWC-2 [1WW2]
  • IPPU-SLAT [4CN]
  • wiring from the FWC2 (1WW2) to the slat IPPU (4CN)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 278501
AMM 27-85-11-000-001
Removal of the Instrumentation Position Pick-Off Unit
AMM 27-85-11-400-001
Installation of the Instrumentation Position Pick-Off Unit
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-710-192-A
A. Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-128-A
A. If the test gives the maintenance message FWC2: RH SLT SYNC 4CNB:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the FWC2 (1WW2) to the slat IPPU (4CN), between pins AD/13A, 13B, 13C and pins B/C, D, E ASM 278501.
Subtask 31-53-00-710-193-A
B. Do the test given in Para. 3.