Loss of the LH SLT SYNC Signal Output by the FWC 1
TASK 31-53-00-810-876-A
Loss of the LH SLT SYNC Signal Output by the FWC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-186-A 4. Fault Isolation
Subtask 31-53-00-810-125-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:16 UTC
Loss of the LH SLT SYNC Signal Output by the FWC 1
1. Possible Causes
- FWC-1 [1WW1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 278501 | |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-186-A 4. Fault Isolation
Subtask 31-53-00-810-125-A
A. If the test gives the maintenance message FWC1: LH SLT SYNC 4CNA:
Subtask 31-53-00-710-187-A - replace the FWC-1 [1WW1] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the wiring from FWC1 (1WW1) pins AA/13G, 13H, 13J to the first terminal block ASM 278501.
B. Do the test given in Para. 3.