W DOC AIRBUS | TSM A320F

Loss of the EIU 1 Bus of the FWC 1


TASK 31-53-00-810-860-A
Loss of the EIU 1 Bus of the FWC 1


1. Possible Causes
  • FWC-1 [1WW1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315203
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-710-154-A
A. Test
Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-109-A
A. If the test gives the maintenance message FWC1 : NO DATA FROM EIU1:
   (1) If the fault continues:
  • do a check and repair the wiring from FWC 1 (1WW1) pins AB/8C, 8D to the first terminal block , ASM 315203.
Subtask 31-53-00-710-155-A
B. Do the test given in Para. 3.