W DOC AIRBUS | TSM A320F

Loss of the FQI 1A Bus of the FWC 1


TASK 31-53-00-810-818-A
Loss of the FQI 1A Bus of the FWC 1


1. Possible Causes
  • FWC-1 [1WW1]
  • wiring from FWC 1 (1WW1) pins AB/7A, 7B to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315203
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-53-00-710-070-A
A. Test
   (1) Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-53-00-810-067-A
A. If the test gives the maintenance message FWC 1 : NO DATA FROM FQI 1A/1B:
   (1) If the fault continues:
  • do a check and repair the wiring from FWC 1 (1WW1) pins AB/7A, 7B to the first terminal block, ASM 315203.
Subtask 31-53-00-710-071-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:12 UTC