Loss of the ARINC 429 Data between the FWC 1 and the DMC 3
TASK 31-53-00-810-813-A
Loss of the ARINC 429 Data between the FWC 1 and the DMC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-865-056-A
Subtask 31-53-00-810-062-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:12 UTC
Loss of the ARINC 429 Data between the FWC 1 and the DMC 3
1. Possible Causes
- FWC-1 [1WW1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 315205 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
Subtask 31-53-00-865-056-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-53-00-740-062-A ** ON A/C NOT FOR ALL Subtask 31-53-00-740-062-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
Subtask 31-53-00-810-062-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC3 : NO FWC 1 DATA
Subtask 31-53-00-810-062-B ** ON A/C NOT FOR ALL DMC3 : NO FWC 1 DATA
- replace the FWC-1 [1WW1] , AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the wiring from the FWC 1 (1WW1) pins AB/12J, 12K to the first terminal block , ASM 315205.
A. If the test gives the maintenance message:
FWC1(1WW1) BUSX DATA/DMC3(1WT3)
Subtask 31-53-00-740-063-A FWC1(1WW1) BUSX DATA/DMC3(1WT3)
- replace the FWC-1 [1WW1] , AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the wiring from the FWC 1 (1WW1) pins AB/12J, 12K to the first terminal block , ASM 315205.
B. Do the test given in Para. 3.B.