W DOC AIRBUS | TSM A320F

Loss of the ARINC 429 Data between the FWC 1 and the DMC 2


TASK 31-53-00-810-811-A
Loss of the ARINC 429 Data between the FWC 1 and the DMC 2


1. Possible Causes
  • DMC-2 [1WT2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 315205
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-53-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFWS/FWC1/SPLY3WWF01
Subtask 31-53-00-740-058-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test (EIS 2) AMM 31-60-00-740-002.
Subtask 31-53-00-740-058-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007
4. Fault Isolation
Subtask 31-53-00-810-060-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC 2 : NO FWC 1 DATA
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 2 (1WT2) pins AA/10A, 10B to the first terminal block , ASM 315205.
Subtask 31-53-00-810-060-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
FWC1(1WW1) BUSx DATA/DMC2(1WT2)
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 2 (1WT2) pins AD/8G, 8H to the first terminal block , ASM 315205.
Subtask 31-53-00-740-059-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:30:11 UTC