Loss of the ARINC 429 Output Bus from the FWC 2 to the FWC 1
TASK 31-53-00-810-802-A
Loss of the ARINC 429 Output Bus from the FWC 2 to the FWC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-53-00-710-052-A 4. Fault Isolation
Subtask 31-53-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:11 UTC
Loss of the ARINC 429 Output Bus from the FWC 2 to the FWC 1
1. Possible Causes
- FWC-2 [1WW2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 315205 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 31-53-00-710-052-A 4. Fault Isolation
Subtask 31-53-00-810-051-A
A. If the test gives the maintenance message:
NO DATA FROM OPPOSITE FWC
Subtask 31-53-00-710-053-A NO DATA FROM OPPOSITE FWC
- replace the FWC-2 [1WW2] , AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- do a check and repair the wiring from the FWC 2 (1WW2) pins AE/12B, 12C to the first terminal block, ASM 315205.