W DOC AIRBUS | TSM A320F

Disagree between FWC1 and FWC2 OEB DATABASE


TASK 31-51-00-810-811-A
Disagree between FWC1 and FWC2 OEB DATABASE


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-51-00-210-001
Read OEB REMINDER Data in the FWC1 and/or the FWC2.
AMM 31-51-00-610-002
Delete OEB REMINDER Data from FWCs using MCDUs.
AMM 31-51-00-610-003
Crossload OEB REMINDER Data into FWCs using MCDUs.
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 31-51-00-710-050-A
A. Not applicable
4. Fault Isolation
Subtask 31-51-00-810-060-A
A. If the fault symptom is identified by the FWS OEB/FWC DISCREPANCY ECAM warning:
   (1) Read OEB reminder information in the FWC1 and FWC2 AMM 31-51-00-210-001.
     (a) Record of the incorrect ECAM 1 or 2 OEB data base list
     (b) Delete the incorrect OEB reminder information from the related FWC AMM 31-51-00-610-002.
     (c) Crossload OEB reminder information, from the FWC which has the correct data base to the FWC which had the incorrect data base. AMM 31-51-00-610-003.
   (2) If the fault continues:
     (a) Replace the defective FWC-1 [1WW1] or FWC-2 [1WW2] AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
Subtask 31-51-00-710-051-A
B. Make sure that the FWS OEB/FWC DISCREPANCY ECAM warning is not shown on the upper ECAM DU.
[Rev.8 from Aug 2018] 2026.04.04 04:30:11 UTC